The failure loads of the spinal column were 1774.8 +/- 672.3 N and 1501.2 +/- 556.5 N in the P group and C group, respectively. There was no significant difference in the failure load of the spinal column between each group.
Conclusion. New vertebral
fractures occurred at the vertebra adjacent to augmented vertebrae in the P group and in the augmented vertebrae in the C group. The difference in the fractured site may be because of the difference in strength between the 2 bone filler materials. Therefore, the strength of bone filler materials is considered a risk CUDC-907 purchase factor in developing adjacent vertebral body fractures after VP.”
“(PACE 2009; e4-e6).”
“Background/Objectives: Cardiac MRI (CMR) is increasingly used for surgical planning and serial monitoring of children with congenital heart disease (CHD). For small children, general anesthesia (GA) is required. We describe our experience of the safety of GA for pediatric CMR, using data collected prospectively over 3 years.
Methods: All consecutive infants undergoing GA for CMR at our institution, between November 2005 and May 2008, were included. Informed and written consent to participate in research investigation was acquired from the guardians of every patient
prior to CMR. The cardiac anesthetist completed a standardized data collection form during each procedure. Information collected included demographics, diagnosis, surgical history, anesthetic management, significant incidents, and discharge circumstances.
Results: Go6983 A total of 120 patients buy MK-8931 with varying cardiac physiology and a range of hemodynamics underwent GA for CMR during the study period. Gas induction was predominantly used, even in those with
impaired ventricular function. The majority (71%) of procedures were undertaken without significant incident. Minor adverse incidents were recorded in 32 patients, mild hypotension being most frequent. One major adverse event occurred. A patient with hypoplastic left heart syndrome (HLHS) suffered hypotension then cardiac arrest in the scanner. This patient was successfully resuscitated.
Conclusion: Although the majority of cases were safe and without incident, the complication rate in children with CHD receiving a GA for CMR is higher than in the general pediatric population. This reinforces the need for a senior, multidisciplinary team to be involved in the care of these children during imaging.”
“Study Design. In vitro biomechanical study on 6 fresh frozen human thoracolumbar spine specimens.
Objective. Using a novel high viscosity polymethylmethacrylate (PMMA) cement and vertebroplasty kit to correct the kyphosis angle of wedge compression fractures (AO/ASIF 1.2).
Summary of Background Data. Vertebroplasty is typically used to stabilize vertebral compression fractures in situ without correcting kyphosis, with the main target to reduce pain and disability.