In an effort to develop effective platelet tests for potential use in medical device evaluation, this study compared the sensitivity of platelet responses to shear stress stimulation of human and bovine blood using multiple platelet activation markers. Fresh whole blood samples anticoagulated with heparin or anticoagulant citrate dextrose, solution A (ACDA) were exposed to shear stresses up to 40Pa
for 2min using a cone-and-plate rheometer model. Platelet activation was characterized by platelet counts, platelet surface P-selectin expression, and serotonin release into blood plasma. The results indicated that VX-680 mw exposure to shear stresses above 20Pa caused significant changes in all three of the platelet markers for human blood and that the changes were usually greater with ACDA anticoagulation than with heparin. In contrast, for bovine blood, the markers did not change with shear stress stimulation except for plasma serotonin in heparin anticoagulated blood. The differences observed between human and bovine platelet responses suggest that the value of using bovine blood for in vitro platelet testing Proteasome function to evaluate devices may be limited.”
“Objective. The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses
with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. Methods. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. Results. The results of the finite element analysis
in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis selleck inhibitor under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). Significance. By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments.