“
“Erratum to: Clin Exp Nephrol DOI 10.1007/s10157-009-0256-5 The authors’ affiliations appeared incorrectly in the article cited above. The correct affiliations are as follows: H. A. Omar · M. A. Alzahrani · A. A. A. Al bshabshe · A. Assiri · M. Shalaby · A. Dwedar Department of Medicine, College of Medicine, King Khalid University and Asser Central Hospital, Abha, Kingdom of Saudi Arabia”
“Erratum to: Clin Exp Nephrol (2004) 8:183–187 DOI 10.1007/s10157-004-0307-x This article has been retracted ��-Nicotinamide order because it cited
as a major source the article “Combination treatment of angiotensin-II receptor blocker and angiotensin-converting-enzyme inhibitor in non-diabetic renal disease (COOPERATE): a randomised controlled trial”, which had been retracted by The Lancet. The editors, Clinical and Experimental Nephrology”
“Erratum to: Clin Exp Nephrol DOI 10.1007/s10157-009-0199-x In Table 3, in the column headed “Proteinuria (+)”, the “Estimated number of Japanese adults in 2005” in the 30–59 age-group should be 823881, not 8238881. The corrected table is shown here. Table 3 Prevalence rates of CKD stages in Japanese adults (20 years or older), and estimated number of CKD cases per CKD stage based
on the 2005 census GFR (ml/min/1.73 m2) Total Proteinuria (+) Proteinuria (−) Prevalence rate (%) GFR selleckchem ≥90 27.8 0.6 27.2 60–89 61.6 1.7 60.0 30–59 10.4 0.8 9.6 <30 0.2 0.1 0.1 Stage 3 50–59 7.6 0.4 7.2 40–49 2.3 0.3 2.0 30–39 0.6 0.1 0.4 Estimated Isotretinoin number of Japanese adults in 2005 GFR ≥90 28639274 605313 28033961 60–89 63576938 1708870 61868068 30–59 10743236 823881 9919355
<30 236569 125190 111379 Stage 3 50–59 7809261 425146 7384116 40–49 2363987 267158 2096828 30–39 569988 131577 438411"
“Erratum to: Clin Exp Nephrol DOI 10.1007/s10157-009-0192-4 Errors appeared in the article cited above, as follows: Abstract: There was a mistake in the third sentence. The sentence should read: A newly developed, programmable HBPM device (HEM-5041, Omron Healthcare, Kyoto, Japan) can record blood pressure up to 600 times and measure nighttime blood pressure automatically. Introduction, second paragraph, lines 10–11: The sentence should read: A recently developed HBPM device (HEM-5041, Omron Healthcare, Kyoto, Japan) can record blood pressure 600 times in total and be programmed to measure blood pressure up to 20 times during the night. Table 2: In the first column, “Daytime” should have been “Whole day” and “Nighttime” should have been “Daytime”. The corrected table is as follows: Table 2 Comparisons of percentage nighttime fall HBPM ABPM P Whole day SBP 5.0 ± 0.8 11.6 ± 0.7 <0.0001 DBP 8.6 ± 1.2 16.1 ± 1.0 <0.0001 PR/HR 9.1 ± 1.2 18.9 ± 1.0 <0.0001 Daytime SBP 5.3 ± 1.0 14.7 ± 0.9 <0.0001 DBP 9.6 ± 1.4 19.9 ± 1.1 <0.0001 PR/HR 7.4 ± 1.4 23.5 ± 1.2 <0.