Pill-taking was tracked for 3 months by an electronic monitoring

Pill-taking was tracked for 3 months by an electronic monitoring device with wireless data collection. During the study period, participants assigned the intervention received a daily reminder text message. Eighty-two women were assigned randomly to detect a 1.6 +/- 2.0 pill difference Kinase Inhibitor Library nmr ( 90% power, 5% alpha, 15% dropout).

RESULTS: Participants were 79% white, non-Hispanic, 99% high school graduates, and 99% nulliparous with a mean age of 22 years. Most reported condom use with past coital activity, and more than half reported prior emergency contraception use. The mean number of

missed pills per cycle did not differ significantly between the groups: 4.9 +/- 3.0 for the text-message group and 4.6 +/- 3.5 for the control group (P = .60). The number of missed pills per cycle increased over the MLN2238 mouse course of the study, but this pattern did not increase differentially between the groups. Adherence

recorded by the electronic monitoring device indicated much poorer adherence than that recorded by patient diaries. Despite poor pill-taking, there were no pregnancies.

CONCLUSION: Daily text-message reminders did not improve oral contraceptive pill adherence. Although the lack of benefit may be attributed to the frequent use of alternative reminder systems in the control group, the rate of missed pills when measured objectively was still very high in both groups.”
“Medical investigations targeting a quantitative analysis of the position emission tomography (PET) images require the incorporation of additional knowledge about the photon attenuation distribution in the patient. Today, energy

range adapted attenuation maps derived from computer tomography (CT) scans are used to effectively compensate for image quality degrading effects, such as attenuation and scatter. Replacing CT by magnetic CAL-101 ic50 resonance (MR) is considered as the next evolutionary step in the field of hybrid imaging systems. However, unlike CT, MR does not measure the photon attenuation and thus does not provide an easy access to this valuable information. Hence, many research groups currently investigate different technologies for MR-based attenuation correction (MR-AC). Typically, these approaches are based on techniques such as special acquisition sequences (alone or in combination with subsequent image processing), anatomical atlas registration, or pattern recognition techniques using a data base of MR and corresponding CT images. We propose a generic iterative reconstruction approach to simultaneously estimate the local tracer concentration and the attenuation distribution using the segmented MR image as anatomical reference. Instead of applying predefined attenuation values to specific anatomical regions or tissue types, the gamma attenuation at 511 keV is determined from the PET emission data.

Comments are closed.